QUANTI H500 Hematology Analyzer

Information regarding the presence and concentration of various blood components will assist a physician to identify a patient's disease and/or the potential cause of a given disease. To eliminate any false positive or false negative results it is important that the blood sample is prepared accurately. The QUANTI H500 is a compact benchtop system that provides an accurate, effective, reliable and rapid solution for blood analysis.
Integrating the QUANTI H500 with our VERSA liquid handling system provides benefits that include automatic dilution and preparation of blood sample, auto-sampling and testing 23 different parameters with 3 part WBC differentiation. The QUANTI H500 rapidly determines the presence, number and type of cellular elements in the blood. Performance is enhanced by utilizing up to 4 quality control methods (X-B, L-J, SD, CV). The system’s low minimum sample volume allows for use in a variety of applications. The aspiration/dispensing tube is automatically cleaned after every measurement using a high-voltage cleaning system, thereby improving accuracy and reducing carry over.
Features and Benefits
• Ideal for routine testing in small to medium laboratories
• Automatic and manual calibration provides reliable performance, less down time, and simpler repairs
• Results are obtained in less than a minute
• Automatic dilution, possible even when power to analyzer is off
• High voltage cleansing after each measurement avoids carryover
• 23 non-cellular parameters provide a wide test range
• Increases productivity and linearity
• Multiple quality control methods available: X-B, L-J, SD and CV
• Fast, accurate, reliable results
• Fully-automated analyzer
• Easy to use
Analytes Tested
• WBC
• Lymph
• Mid
• Gran
• Lymph%
• Gran%
• RBC
• HGB
• HCT
• MCV
• MCHC
• RDW-SD
• RDW-CV
• PLT
• MPV
• PCT
• WBC Histogram
• RBC Histogram
• PLT Histogram
• P-LCR
Specifications
System Components and Hardware
• Parameters 23 with 3 part WBC differential
• Aperture Diameter 70 μm
• Sampler Volume 10 μL
• Memory 30,000 tests including histograms
• Throughput 35 samples/hour
• Working mode Single counting pathway + Independent HGB detection system
Performance
• Parameters Linearity Range Precision
• WBC 0.5 - 99.9×10 9 /L CV < 2.0%
• RBC 0.2 - 9.99×10 12 /L CV < 1.5%
• HGB 1.0 - 299.9 g/L CV < 1.5%
• MCV 40 - 200 fL CV < 0.5%
• PLT 0 - 999×10 9/L CV < 4.0%
Carryover
• WBC < 0.5%
• RBC < 0.5%
• HGB < 0.5%
• PLT < 2.0%
Operating Conditions
• Temperature 15°C - 30°C
• Humidity 10% - 85%
• Printout Thermal recorder and printer
• Reagent consumed For Lysis, Diluent and Rinsing
• Power requirement 175V - 265V, 50/ 60Hz
• Dimensions (W*D*H) 390mm * 460mm * 400mm
• Weight 20kg
• Optional External printer and/or Bar code scanner
|